waterproof constant pressure variable speed water pump controller

Waterproof Constant Pressure Variable Speed Water Pump pressure inverter

Basic Info


Link of Transformation: AC-DC-AC Variable-Frequency Drive
Nature of DC Power: Voltage Variable-Frequency Drive
Function: Pump Special
Output Power: 750W~1500W
Output Phase: Single
Input Voltage: 220V Single Phase
Output Voltage: 0~220 Three Phase
Type: AC-DC-AC Inverter
Output Frequency: 0~600Hz
Protection Rate: IP54
Color: Black and White
Transport Package: Wooden Cases or as Per Customer′s Requirements
Specification: Depend on model

 

Product Description


B603B series intelligent constant pressure water supply controller is suitable for full-automatic operation, with characteristics of high quality, multi-functional, low noise and strong commonality etc.
There are no special demands for peripherals, it mainly use normal components, for example: Water detection use transducer, transmitter (include water level transmitter, temperature transmitter, etc. ) or inductive remote transmission pressure gauge, with output of 4~20mA, 0~5VDC and 0~10 VDC standard signal.

Power range


I B603 series Intelligent constant pressure pump controller
Single phase 220V input, 3 phase 220V output: 1HP-7HP(0.75KW-2.2KW)
Three phase 220V input, 3 phase 220V output: 1HP-75HP(0.75KW-55KW)
Three phase 380V input, 3 phase 380V output: 1HP-470HP(0.75KW-350KW)

II B603B series Intelligent constant pressure pump controller(water proof)
Single phase 220V input, 3 phase 220V output: 1HP-2HP(0.75KW-2.2KW)
Three phase 220V input, 3 phase 220V output: 1HP-75HP(4KW-7.5KW)
Three phase 380V input, 3 phase 380V output: 1HP-3HP(0.75KW-15KW)

Function characteristics


·Multi-pump control: Can realize 1 master and max. 5 auxiliaries combine work
·Sleep function: Sleep down when have no water consumption, to earn a better energy saving
·Freeze-proofing function: Suitable to low temperature area, prevent pump from freezing
·Anti-clogging function: Take precaution against pipe clogging and clean the pipe dirt
·Power on restart: Running automatically when power on
·Master fault shift automatically: Keep on working when the master break down
·Alternate running: Balance every pump's running time, prolong service life of the whole unit machine
·Day-part function: 3 independent day-part control, up to 7 day-part achieved when define separated
·Two running mode: Synchronous control mode, master-slave control mode
·Terminal control mode: Terminal run/stop, manual/auto control, electronic contact gauge control
·Various of water supply fault alarm function: High-pressure, low-pressure, low-level, transducer error etc.
·As many as 22 kinds of fault protection function: Over-current, over-voltage, low-voltage, phase-failure, over-load etc.

, ,